Botou Jingda Tools and Measuring Instruments Co., Ltd.

Granite Basement of Concetricity Bench Center

Granite Basement of Concetricity Bench Center
Product Detailed

widly used for measuring the axial and disk products and parts,and mainly inspecting their radial bound.

Main technique parameters:

1 The radial circular bound of the Morse No.2 finial 60°cone surface to the Morse cone≤0.005mm;

2 The parallelism between the finial axle within the scope of 100mm and the leading track (parallel and vertical direction)≤0.004mm;

3 The max diameter of the tested part is 270mm;

4 Measuring length300mm500mm1000mm1500mm.

 

  

Size and Technical details :

Type (mm)Center Height (mm)Measuring diamete (mm)Precision
Horizontal (μm)Vertica (μm)
200100200≤ 8≤ 5
300100200≤ 8≤ 5
300170340≤ 8≤ 5
300300600≤ 8≤ 5
500170340≤ 8≤ 5
500250500≤ 8≤ 5
500300600≤ 8≤ 5
1000250500≤ 10≤ 8
1000300600≤ 10≤ 8
1500250500≤ 20≤ 16
2000230460≤ 30≤ 20
2500300   

Your inquiry will be highly appreciated by us .Hope this will be a nice start of our long businese cooperation.